Previous
DCRACK

Bitmain Antminer DCRACK 36KW Asic Miners Air Cooling Cabinet

$19,499
Next

Bitmain Antminer DCTANK AW1 120KW Asic Miners Air Cooling Cabinet

$64,549
Next Product Image

Bitmain Antminer AR1902

$10,529

Category: Tag:

Description

Antminer Antrack AR1902 is a hydro cooling SHA-256 mining package designed for BTC, BCH, and BSV mining. It offers 1172Th total hashrate, 32KW power capacity, and 80°C heating performance, making it a powerful complete hydro cooled setup for miners who need advanced cooling efficiency, stable output, and large-scale mining performance.

Specifications

Manufacturer Bitmain
Model ANTRACK V2-EC2-DT
Version V2-EC4-DTHP
Miners capacity 4 units ANTMINER ( Hydro Miner)
4 units ANTMINER (U2 Hydro)
2 units ANTMINER (U3 Hydro)
Maximum load, kW 32kW
Mining Cabinet
Overall Dimensions (w/o) 1200 x 600 x 1300mm
Overall Dimensions (with) 1460 x 1330 x 780mm
Overall Weight Net 130kg
Overall Weight Gross 185kg
Network Connection Mode RJ45 Ethernet 10/100M
Input Voltage 380-415v
Input frequency range  50-60
Input current, Amp(1-2)  63
Rated power, W 450
Noise, dBA@1m 60
Lift, m 19
Size (Length*Width* Height), mm 360 x 210 x 268mm
Maximum heat exchange power, kW 30
Size (Length*Width* Height), mm 305 x 106 x 64mm
Diameter of water pipe connector, mm DN20
External Cooler(1-3)
Hardware Configuration
Size (Length*Width*Height), mm (w/o) 1340 x 570 x 1330mm
Size (Length*Width*Height), mm (w) 1490 x 590 x 1495mm
Net weight, kg 235
Gross weight, kg 248
Power supply AC input voltage, Volt(1-1) 380~415V
Power supply AC input frequency range, Hz 50~60
Maximum power supply AC input current, Amp(1-2) 21
Heating Capacity (typical), kW 32
Compressor Input (typical), kW 8
EER (typical) 3.0
Sound Level, Db(A) 50
Refrigerant R290
Heating water outlet Temperature, °C 80
Fan – Rated power, W 500
Noise, dBA@1m 50db
Size (Length*Height*Thickness), mm 551 x 551 x 160mm
Water pump – Rated power, W 180
Noise, dBA@1m 30db
Size (Length*Width* Height), mm 130 x 551 x 129mm
Environment Requirements
Ambient temperature, °C -20~40
Water flow, L/min 32.0~40.0 (Cabinet side)
Water flow, L/min 32.0~40.0 (Heating side)
Water pressure, bar ≤3.5
Working fluid(1-4) Organic Antifreeze (10%)
Installation distance, m(1-5) 50
Liquid PH 7.8~8.5
Storage temperature, °C -20~70
Operation humidity(non-condensing), RH 10~90%